CAD Details

Λεπτομέρειες εφαρμογής Συστημάτων Εξωτερικής Θερμομόνωσης StoTherm

Συστήματα StoTherm – Βασικές λεπτομέρειες

No. Description PDF DWG
Sto-HQ-EN_GEN-0001_2023-10-01 Overview PDF DWG
Sto-HQ-EN_GEN-0002_2023-10-01 Overview PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0010_2018-05-01 System section (vertical section): System structure with dowelling and bonding PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0100_2023-01-01 Plinth (vertical section): Ground and splash water zone PDF DWG
Sto-HQ-EN_GEN-0105_2023-01-01 Plinth (vertical section): Ground and splash water zone with floor covering PDF DWG
Sto-HQ-EN_GEN-0110_2018-05-01 Plinth (vertical section): Ground and splash water zone with Sto-Perimeter Insulation Board and perimeter insulation already available on-site PDF DWG
Sto-HQ-EN_GEN-0111_2018-05-01 Plinth (vertical section): Ground and splash water zone with Sto-Perimeter Insulation Board and perimeter insulation already available on-site, increased moisture protection PDF DWG
Sto-HQ-EN_GEN-0112_2018-05-01 Plinth (vertical section): Ground and splash water zone with Sto-Perimeter Insulation Board and perimeter insulation already available on-site, increased moisture protection PDF DWG
Sto-HQ-EN_GEN-0115_2018-05-01 Plinth (vertical section): Ground and splash water zone with perimeter insulation already available on-site PDF DWG
Sto-HQ-EN_GEN-0125_2018-05-01 Plinth (vertical section): Splash water zone, above ground level PDF DWG
Sto-HQ-EN_GEN-0135_2018-05-01 Plinth (vertical section): Ground and splash water zone with insulation board projection PDF DWG
Sto-HQ-EN_GEN-0136_2018-05-01 Plinth (vertical section): Ground and splash water zone with insulation board projection and retrofitted plinth insulation PDF DWG
Sto-HQ-EN_GEN-0137_2018-05-01 Plinth (vertical section): Ground and splash water zone with insulation board projection and retrofitted plinth insulation with StoFlexyl PDF DWG
Sto-HQ-EN_GEN-0140_2023-07-01 Plinth (vertical section): Splash water zone with floor covering already available on site, used in refurbishment PDF DWG
Sto-HQ-EN_GEN-0141_2018-05-01 Plinth (vertical section): Connection to a step PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0200_2018-05-01 External wall / system transition (horizontal section): Connection to an old-render facade using joint sealing tape PDF DWG
Sto-HQ-EN_GEN-0210_2018-07-01 External wall / system transition (horizontal section): Connection in an internal corner PDF DWG
Sto-HQ-EN_GEN-0215_2018-05-01 External wall / system transition (horizontal section): Connection to an old-render facade using mesh backing PDF DWG
Sto-HQ-EN_GEN-0220_2018-05-01 External wall / system transition (horizontal section): Connection to an old-render facade using mesh backing, facade insulation around the external corner PDF DWG
Sto-HQ-EN_GEN-0225_2018-05-01 External wall / system transition (horizontal section): Flush connection to an old-render facade PDF DWG
Sto-HQ-EN_GEN-0230_2018-05-01 External wall / system transition (vertical section): Connection to a preplaced concrete element without sheet metal covering PDF DWG
Sto-HQ-EN_GEN-0235_2018-05-01 External wall / system transition (vertical section): Connection to a preplaced concrete element with sheet metal covering PDF DWG
Sto-HQ-EN_GEN-0240_2018-05-01 External wall / system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0241_2023-10-01 External wall / system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0243_2018-05-01 External wall / system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0244_2022-09-01 External wall / system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0245_2018-05-01 External wall / system transition (vertical section): Transition between different building elements using an expansion joint profile PDF DWG
Sto-HQ-EN_GEN-0250_2020-07-01 External wall / system transition (vertical section): Lamp fixing PDF DWG
Sto-HQ-EN_GEN-0260_2018-05-01 External wall / system transition (vertical section): Connection to an integrated building element PDF DWG
Sto-HQ-EN_GEN-0265_2018-05-01 External wall / system transition (vertical section): Lamp fixing PDF DWG
Sto-HQ-EN_GEN-0270_2018-05-01 External wall / system transition (vertical section): Awning fixing PDF DWG
Sto-HQ-EN_GEN-0271_2023-10-01 External wall/system transition (vertical section): Installation of StoFix Zyrillo PDF DWG
Sto-HQ-EN_GEN-0272_2023-10-01 External wall/system transition (vertical section): Installation of StoFix Ashlar HD Maxi PDF DWG
Sto-HQ-EN_GEN-0273_2023-10-01 External wall/system transition (vertical section): Installation of StoFix Ashlar ND Mini, StoFix Ashlar ND Midi or StoFix Ashlar Quick PDF DWG
Sto-HQ-EN_GEN-0275_2023-10-01 External wall / system transition (vertical section): Drip edge with drip edge profile PDF DWG
Sto-HQ-EN_GEN-0276_2018-05-01 External wall / system transition (vertical section): Drip edge with drip edge profile in case of a ceiling projection PDF DWG
Sto-HQ-EN_GEN-0280_2018-05-01 External wall / system transition (horizontal section): Connection of the facade insulation around the external corner, bonding and dowelling PDF DWG
Sto-HQ-EN_GEN-0285_2018-05-01 External wall / system transition (horizontal section): Fall protection fixing PDF DWG
Sto-HQ-EN_GEN-0286_2018-05-01 External wall/system transition (horizontal section): Fall protection fixing with StoFix Installation Angle PDF DWG
Sto-HQ-EN_GEN-0290_2018-05-01 External wall / system transition (vertical section): Rainwater pipe fixing PDF DWG
Sto-HQ-EN_GEN-0295_2018-05-01 External wall / system transition (horizontal section): Connection to a rainwater pipe with additional insulation of ≥ 4 cm PDF DWG
Sto-HQ-EN_GEN-0296_2018-05-01 External wall / system transition (horizontal section): Connection to a rainwater pipe with additional insulation of < 4 cm PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0300_2018-05-01 Roof (vertical section): Connection to a ventilated roof construction PDF DWG
Sto-HQ-EN_GEN-0305_2018-05-01 Roof (vertical section): Connection to a non-ventilated roof construction PDF DWG
Sto-HQ-EN_GEN-0310_2018-05-01 Roof (vertical section): Connection of a lean-to roof PDF DWG
Sto-HQ-EN_GEN-0315_2018-05-01 Roof (vertical section): Connection to a roof projection on the gable side PDF DWG
Sto-HQ-EN_GEN-0320_2018-05-01 Roof (vertical section): Connection of a roof side PDF DWG
Sto-HQ-EN_GEN-0330_2018-05-01 Roof (vertical section): Connection to a parapet PDF DWG
Sto-HQ-EN_GEN-0335_2018-05-01 Roof (vertical section): Connection to a parapet with a parapet profile in case of little distance to the sheet metal covering PDF DWG
Sto-HQ-EN_GEN-0335-01_2020-01-01 Roof (vertical section): Connection to a parapet with a parapet profile in case of little distance to the sheet metal covering PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0400_2020-08-01 Reveal/lintel (views): Arrangement of insulation boards and diagonal reinforcement PDF DWG
Sto-HQ-EN_GEN-0401_2022-05-01 Reveal/lintel (vertical section, view): Connection of the lintel to a set-back window using a seal bead PDF DWG
Sto-HQ-EN_GEN-0405_2018-05-01 Reveal/lintel (vertical section, view): Fire strip at the lintel PDF DWG
Sto-HQ-EN_GEN-0407_2020-08-01 Reveal/lintel (vertical section): All-around fire strip PDF DWG
Sto-HQ-EN_GEN-0413_2021-07-01 Reveal/lintel (horizontal section): Connection to a large window that is flush with the facade or set forward with Sto-Joint Flank Profile PDF DWG
Sto-HQ-EN_GEN-0414_2020-09-01 Reveal/lintel (horizontal section): Connection to a large window that is flush with the facade or set forward with Sto-Joint Flank Profile, laying of the expansion joint tape PDF DWG
Sto-HQ-EN_GEN-0415_2020-07-01 Reveal/lintel (horizontal section): Connection to a large window that is flush with the facade or pre-placed PDF DWG
Sto-HQ-EN_GEN-0416_2018-05-01 Reveal/lintel (views): Connection to a larger window that is flush with the facade or pre-placed, laying of the joint sealing tape PDF DWG
Sto-HQ-EN_GEN-0420_2018-05-01 Reveal/lintel (horizontal section): Connection of the reveal to a window that is flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0425_2021-07-01 Reveal/lintel (horizontal section): Connection of the StoFentra Duo and the StoElement Pronto L-100 / L-300 with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0430_2018-05-01 Reveal/lintel (horizontal section): Connection of the reveal to a pre-placed window using a seal bead PDF DWG
Sto-HQ-EN_GEN-0431_2018-05-01 Reveal/lintel (horizontal section): Connection of the reveal to a pre-placed window using joint sealing tape PDF DWG
Sto-HQ-EN_GEN-0440_2018-05-01 Reveal/lintel (horizontal section): Connection of the reveal to a pre-placed window with insulation on the window frame PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0500_2018-05-01 Window sill (vertical section): Connection of StoFentra Profi PDF DWG
Sto-HQ-EN_GEN-0505_2018-05-01 Window sill (vertical section): Connection of StoFentra Uni PDF DWG
Sto-HQ-EN_GEN-0510_2018-05-01 Window sill (vertical section): Connection of the StoFentra Duo with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0511_2018-05-01 Window sill (vertical section): Connection of the StoFentra Duo using the StoFentra Guard waterproofing system PDF DWG
Sto-HQ-EN_GEN-0512_2019-09-01 Window sill (vertical section): Connection of the StoFentra Duo and the StoElement Pronto L-100 / L-300, StoElement Pronto K-100 / K-300 with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0515_2018-05-01 Window sill (vertical section): Connection of the Sto-Window Sill Stone without upstand profile using a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0516_2018-05-01 Window sill (vertical section): Connection of a natural stone window sill with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0520_2018-05-01 Window sill (vertical section): Connection of the Sto-Window Sill Stone with upstand profile and a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0530_2018-05-01 Window sill (vertical section): Connection of a window sill with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0531_2018-05-01 Window sill (vertical section): Connection of a window sill with a second waterproofing layer in accordance with the RAL directive PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0600_2023-10-01 Roller shutter/ window blinds (horizontal section): Connection of a shutter guide track with StoFix Cap PDF DWG
Sto-HQ-EN_GEN-0605_2023-10-01 Roller shutter/ window blinds (horizontal section): Connection to a shutter guide track PDF DWG
Sto-HQ-EN_GEN-0610_2023-10-011 Roller shutter/ window blinds (horizontal section): Connection to a shutter guide track, StoFentra Profi Niche PDF DWG
Sto-HQ-EN_GEN-0615_2024-03-01 Roller shutter/window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box with StoPanel Plus (12 mm), without additional insulation PDF DWG
Sto-HQ-EN_GEN-0616_2018-05-01 Roller shutter/ window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box, without additional insulation on the roller shutter box PDF DWG
Sto-HQ-EN_GEN-0620_2018-05-01 Roller shutter/ window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box, with ≥ 4 cm additional insulation on the roller shutter box PDF DWG
Sto-HQ-EN_GEN-0621-2023-08-01 Roller shutter/window blinds (view): Arrangement of insulation boards to a Rev. no. load-bearing and dimensionally stable roller shutter box, with ≥ 4 cm additional insulation PDF DWG
Sto-HQ-EN_GEN-0622_2024-03-01 Roller shutter/window blinds (view): Connection to a load-bearing and dimensionally stable roller shutter box with StoPanel Plus (12 mm), without additional insulation PDF DWG
Sto-HQ-EN_GEN-0624_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a roller shutter cover with StoPanel Plus (12 mm) to a sufficiently load-bearing sub-construction PDF DWG
Sto-HQ-EN_GEN-0625_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a roller shutter cover with StoPanel Plus (12 mm) to a sufficiently load-bearing sub-construction PDF DWG
Sto-HQ-EN_GEN-0626_2018-05-01 Roller shutter/ window blinds (view): Connection of a roller shutter cover with StoPanel Plus (12 mm) to a sufficiently load-bearing sub-construction PDF DWG
Sto-HQ-EN_GEN-0629_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0630_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0632_2018-05-01 Roller shutter/ window blinds (view): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0633_2018-05-01 Roller shutter/ window blinds (view): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) without an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0635_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a non-load-bearing window blind box using the StoFix Trawik L installation element PDF DWG
Sto-HQ-EN_GEN-0636_2018-05-01 Roller shutter/ window blinds (vertical section): Connection of a non-load-bearing window blind box with fixing and thermal separation already available on-site PDF DWG
Sto-HQ-EN_GEN-0650_2022-06-01 Roller shutter/ window blinds (vertical section): Connection of the StoElement JAK window blind box to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0651_2018-05-01 Roller shutter/ window blinds (vertical section): Connection the StoElement JAK window blind box with an optional vacuum panel to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0652_2018-05-01 Roller shutter/ window blinds (vertical section): Connection the StoElement JAK window blind box with an optional vacuum panel to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0655_2018-05-01 Roller shutter/ window blinds (vertical section): Connection the StoElement JAK window blind box to a pre-placed window PDF DWG
Sto-HQ-EN_GEN-0656_2020-03-01 Roller shutter/ window blinds (vertical section): Connection the StoElement JAK-P window blind box PDF DWG
Sto-HQ-EN_GEN-0657_2020-03-01 Roller shutter/window blinds (vertical section): Connection of the StoElement JAS-P window blind box PDF DWG
Sto-HQ-EN_GEN-0658_2018-05-01 Roller shutter/window blinds (vertical section): Connection of the StoElement JAS window blind box PDF DWG
Sto-HQ-EN_GEN-0660_2018-05-01 Roller shutter/ window blinds (vertical section): Connection the StoElement JAK window blind box to a recessed window PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0700_2018-05-01 Balcony/terrace (vertical section): Connection to a thermally separated balcony slab PDF DWG
Sto-HQ-EN_GEN-0705_2023-02-01 Balcony/terrace (vertical section): Connection to a terrace with sheeting already available on-site PDF DWG
Sto-HQ-EN_GEN-0726_2023-02-01 Balcony/terrace (vertical section): Connection to a terrace or a flat roof using liquid synthetic waterproofing (e.g. Kemperol) PDF DWG
Sto-HQ-EN_GEN-0727_2023-10-01 Balcony/terrace (vertical section): Connection to a terrace or a flat roof PDF DWG
Sto-HQ-EN_GEN-0730_2018-05-01 Balcony/terrace (vertical section): Connection of a balcony threshold with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0731_2018-05-01 Balcony/terrace (vertical section): Connection of a balcony threshold with a natural stone window sill and second waterproofing layer in accordance with the RAL directive PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0800_2018-05-01 Structural expansion joint (horizontal section): Joint with Sto-Expansion Joint Profile E PDF DWG
Sto-HQ-EN_GEN-0805_2018-05-01 Structural expansion joint (horizontal section): Joint with Sto-Expansion Joint Profile V in an internal corner PDF DWG
Sto-HQ-EN_GEN-0810_2018-05-01 Structural expansion joint (horizontal section): Joint with expansion joint tape PDF DWG
Sto-HQ-EN_GEN-0815_2018-05-01 Structural expansion joint (horizontal section): Joint with expansion joint tape in an internal corner PDF DWG

Συστήματα StoTherm – Ειδικές λεπτομέρειες

No. Description PDF DWG
Sto-HQ-EN_GEN-0010-01_2020-01-01 System section (vertical section): System structure with dowelling (Sto-Ecotwist) and bonding PDF DWG
Sto-HQ-EN_GEN-0010-02_2021-03-05 System section (vertical section): System build-up with anchors (Sto-Thermo Dowel II UEZ 8/60) and bonding PDF DWG
Sto-HQ-EN_GEN-0050-01_2022-04-26 System section (vertical sectio) and view of a two-layer insulation board installation PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0100-01_2020-01-01 Plinth (vertical section): Ground and splash water zone as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0100-02_2020-01-01 Plinth (vertical section): Ground and splash zone as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0100-03_2020-01-01 Plinth (vertical section): Ground and splash zone as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0100-04_2020-01-01 Plinth (vertical section): Area at risk of impact with StoReno renovation system PDF DWG
Sto-HQ-EN_GEN-0100-05_2020-01-01 Plinth (vertical section): Area at risk of impact with StoPanel Plus (8 mm) PDF DWG
Sto-HQ-EN_GEN-0100-06_2021-09-21 Plinth (vertical section): Ground and splash zone as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0105-01_2020-01-01 Plinth (vertical section): Ground and splash water zone with floor covering as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0111-01_2021-04-07 Plinth (vertical section): Ground and splash water zone with Sto-Perimeter Insulation Board and perimeter insulation already available on-site, increased moisture protection PDF DWG
Sto-HQ-EN_GEN-0112-01_2020-01-01 Plinth (vertical section): Ground and splash zone with Sto-Plinth Insulation Board and perimeter insulation already available on-site, increased moisture protection PDF DWG
Sto-HQ-EN_GEN-0135-01_2020-01-01 Plinth (vertical section): Ground and splash water zone with insulation board projection PDF DWG
Sto-HQ-EN_GEN-0136-03_2020-01-01 Plinth (vertical section): Ground and splash water zone with insulation board projection and retrofitted plinth insulation PDF DWG
Sto-HQ-EN_GEN-0145-01_2020-01-01 Plinth (vertical section): Area at risk of impacts with StoReno renovation system PDF DWG
Sto-HQ-EN_GEN-0150-01_2020-01-01 Plinth (vertical section): Splash water zone with a sloping facade PDF DWG
Sto-HQ-EN_GEN-0110-02_2021-10-08 Plinth (vertical section): Ground and splash zone with floor covering PDF DWG
Sto-HQ-EN_GEN-0110-03_2022-01-10 Plinth (vertical section): Ground and splash zone, connection to a drainage gutter PDF DWG
Sto-HQ-EN_GEN-0111-02_2022-11-08 Plinth (vertical section): Ground and splash zone with Sto-Plinth Insulation Board and perimeter insulation already available on-site PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0200-03_2020-04-01 External wall/system transition (horizontal section): Connection to a precast concrete unit with Sto-Expansion Joint Tape PDF DWG
Sto-HQ-EN_GEN-0200-05_2022-04-28 External wall/system transition (horizontal section, vertical section): Field demarcation joint with Sto-Render Stop Profile, StoSeal sealing tape BUT-105 and joint sealant PDF DWG
Sto-HQ-EN_GEN-0201-01_2022-07-18 External wall/system transition (horizontal section, vertical section): Transition between different building elements with Sto-Joint Flank Profile PDF DWG
Sto-HQ-EN_GEN-0240-22_2021-11-25 External wall/system transition (vertical section): Transition between different insulant thicknesses ≤ 4 cm PDF DWG
Sto-HQ-EN_GEN-0262-01_2022-12-01 External wall/system transition (vertical section): Connection to an integrated building element PDF DWG
Sto-HQ-EN_GEN-0276-03_2020-04-01 External wall/system transition (vertical section): Transition between different insulant thicknesses with Sto-Corner Angle Mesh Roll Ideal PDF DWG
Sto-HQ-EN_GEN-0298-01_2021-02-08 External wall/system transition (horizontal section): Connection to a rainwater pipe with StoPanel Plus PDF DWG
Sto-HQ-DE_GEN-0243-01_2021-02-17 External wall/system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0200-01_2020-02-01 External wall/system transition (horizontal section, vertical section): Field demarcation joint with Sto-Joint Flank Profile and joint sealant PDF DWG
Sto-HQ-EN_GEN-0200-02_2020-02-01 External wall/system transition (horizontal section, vertical section): Field demarcation joint with Sto-Render Stop Profile 10 mm and joint sealant PDF DWG
Sto-HQ-EN_GEN-0205-01_2020-01-01 External wall / system transition (horizontal section): Connection to a ventilated rainscreen cladding facade PDF DWG
Sto-HQ-EN_GEN-0205-02_2020-01-01 External wall / system transition (horizontal section): Varying insulation board thicknesses in two layers PDF DWG
Sto-HQ-EN_GEN-0205-03_2020-01-01 External wall / system transition (horizontal section): Transition between the external wall insulation system and the facing masonry PDF DWG
Sto-HQ-EN_GEN-0210-01_2020-01-01 External wall / system transition (horizontal section): Connection in an internal corner using Sto-Corner Angle Mesh Ideal PDF DWG
Sto-HQ-EN_GEN-0230-01_2021-07-02 External wall/system transition (vertical section): Connection to a preplaced concrete element using joint sealing tape and Sto-Joint Flank Profile PDF DWG
Sto-HQ-EN_GEN-0240-21_2023-03-28 External wall/system transition (vertical section): Transition between different insulant thicknesses ≤ 4 cm PDF DWG
Sto-HQ-EN_GEN-0241-01_2023-02-01 External wall/system transition (vertical section): Transition between different insulant thicknesses with a continuous window sill PDF DWG
Sto-HQ-EN_GEN-0241-02_2023-02-01 External wall/system transition (vertical section): Transition between different insulant thicknesses with a continuous window sill PDF DWG
Sto-HQ-EN_GEN-0241-03_2019-08-20 External wall/system transition (vertical section): Transition between different insulant thicknesses with a continuous window sill and StoElement Pronto KX-100 PDF DWG
Sto-HQ-EN_GEN-0241-04_2019-08-20 External wall/system transition (vertical section): Transition between different insulant thicknesses with a continuous window sill and StoElement Pronto KX-100 / KX-300 PDF DWG
Sto-HQ-EN_GEN-0244-01_2019-03-22 External wall/system transition (vertical section): Transition between different insulant thicknesses PDF DWG
Sto-HQ-EN_GEN-0244-02_2021-06-14 External wall/system transition (vertical section): Transition between different insulant thicknesses with StoElement Pronto KX-100 / KX-300 PDF DWG
Sto-HQ-EN_GEN-0252-01_2020-01-01 External wall/system transition (vertical section): Transition between different rendered surfaces using a render separation profile PDF DWG
Sto-HQ-EN_GEN-0260-01_2020-01-01 External wall / system transition (vertical section): Connection to a ventilation pipe PDF DWG
Sto-HQ-EN_GEN-0260-02_2020-01-01 External wall / system transition (vertical section): Connection to small building elements ≤ 50 / 50cm PDF DWG
Sto-HQ-EN_GEN-0260-03_2020-01-01 External wall / system transition (vertical section): Connection to small building elements ≤ 50 / 50cm PDF DWG
Sto-HQ-EN_GEN-0271-01_2021-07-30 External wall/system transition (vertical section): Connection to a StoFix SLK-ALU-TQ / StoFix SLK-ALU-TR PDF DWG
Sto-HQ-EN_GEN-0275-01_2020-01-01 External wall / system transition (vertical section): Drip edge with drip edge profile PDF DWG
Sto-HQ-EN_GEN-0275-02_2019-08-01 External wall/system transition (vertical section): Transition between the external wall insulation system and a ventilated rainscreen cladding facade PDF DWG
Sto-HQ-EN_GEN-0276-01_2020-01-01 External wall/system transition (vertical section): Drip edge with Sto-Armour Angle and Sto-Render Stop Profile in case of a ceiling projection with horizontal rounding PDF DWG
Sto-HQ-EN_GEN-0276-02_2020-01-01 External wall/system transition (vertical section): Transition between different insulant thicknesses with Sto-Corner Angle Mesh Roll Ideal PDF DWG
Sto-HQ-EN_GEN-0280-01_2019-03-20 undefined PDF DWG
Sto-HQ-EN_GEN-0280-03_2019-08-01 External wall/system transition (horizontal section): Connection of the external wall insulation around the outer corner to an existing ventilated rainscreen cladding façade. PDF DWG
Sto-HQ-EN_GEN-0285-01_2023-07-07 External wall/system transition (horizontal section): Connection of wall construction made of a timber stud wall with boarding around the outer corner to an external wall insulation system. PDF DWG
Sto-HQ-EN_GEN-0285-02_2023-07-07 External wall/system transition (horizontal section): Connection of wall construction made of cross laminated timber with boarding around the outer corner to an external wall insulation system. PDF DWG
Sto-HQ-EN_GEN-0290-01_2020-01-01 External wall / system transition (vertical section): Rainwater pipe fixing using Thermax stand-off installation from Fischer PDF DWG
Sto-HQ-EN_GEN-0297-01_2020-01-01 External wall / system transition (horizontal section): Shaft made of StoPanel Plus (12 mm) for the pipes situated in the insulation layer PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0330-03_2020-10-16 Roof (vertical section): Connection to a parapet, with Metal sheet PDF DWG
Sto-HQ-EN_GEN-0351-01_2022-01-05 Roof (vertical section): Connection of a parapet with a metal capping, joint sealing tape and joint sealant, subsequent fixing of the connection plate PDF DWG
Sto-HQ-EN_GEN-0305-01_2020-01-01 Roof (vertical section): Connection to a non-ventilated roof construction using a Sto-Parapet Profile PDF DWG
Sto-HQ-EN_GEN-0305-02_2018-09-11 Roof (vertical section): Connection to a non-ventilated roof construction using a roof box PDF DWG
Sto-HQ-EN_GEN-0320-01_2020-01-01 Roof (vertical section): Connection to a dormer wall PDF DWG
Sto-HQ-EN_GEN-0325-01_2020-01-01 Roof (vertical section): Connection of a parapet PDF DWG
Sto-HQ-EN_GEN-0340-01_2020-01-01 Roof (vertical section): Connection to a parapet with a cover made of natural stone PDF DWG
Sto-HQ-EN_GEN-0350-01_2020-01-01 Roof (vertical section): Connection of a parapet PDF DWG
Sto-HQ-EN_GEN-0390-01_2022-09-08 Roof (vertical section): Connection of a internal drainage gutter with StoPanel Plus PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0421-02_2021-12-21 Reveal/lintel (horizontal section): Connection of a rounded reveal to a window that is flush with the masonry using a seal bead PDF DWG
Sto-HQ-EN_GEN-0442-01_2021-12-01 Reveal/lintel (horizontal section): Connection of the StoElement Pronto P-101 / P-300 and StoFentra Profi to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0400-01_2023-07-20 Reveallintel (views) Arrangement of insulation boards in accordance with BFS Data Sheet Nr. 21 PDF DWG
Sto-HQ-EN_GEN-0401-01_2021-06-28 Reveallintel (vertical section) Connection of the lintel to a set-back window made of timber and aluminium using a seal bead PDF DWG
Sto-HQ-EN_GEN-0401-03_2021-06-28 Reveallintel (vertical section) Connection of the lintel to a set-back window made of timber and aluminium using a seal bead PDF DWG
Sto-HQ-EN_GEN-0403-01_2021-06-28 Reveallintel (vertical section) Connection of the lintel to a window made of timber and aluminium flush with the masonry using a seal bead PDF DWG
Sto-HQ-EN_GEN-0410-01_2020-01-01 Reveallintel (horizontal section) Connection to a large window that is flush with the facade or set forward with a sheet metal framing available on-site PDF DWG
Sto-HQ-EN_GEN-0410-02_2020-04-07 Reveallintel (vertical section) Connection to a large set-back window with expansion joint tape and Sto-Render Stop Profile PDF DWG
Sto-HQ-EN_GEN-0413-01_2021-03-01 Reveallintel (horizontal section) Connection to a post and beam construction with Sto-Joint Flank Profile PDF DWG
Sto-HQ-EN_GEN-0415-01_2020-01-01 Reveallintel (horizontal section) Connection to a large window that is flush with the facade or set forward with a sheet metal framing available on-site PDF DWG
Sto-HQ-EN_GEN-0415-02_2022-11-09 Reveallintel (horizontal section) Connection to a window with a sheet metal framing installed afterwards PDF DWG
Sto-HQ-EN_GEN-0420-01_2021-06-28 Reveallintel (horizontal section) Connection of the reveal to a window made of timber and aluminium that is flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0421-01_2020-05-20 Reveallintel (horizontal section) Connection of the reveal to a window flush with the masonry using joint sealing tape and render stop profile PDF DWG
Sto-HQ-EN_GEN-0422-01_2021-06-25 Reveallintel (horizontal section) Connection of the reveal to a window flush with the masonry using a seal bead and StoFentra Gutter Profi PDF DWG
Sto-HQ-EN_GEN-0422-02_2021-08-05 Reveallintel (horizontal section) Connection of the reveal in an internal corner with a window flush with the masonry using a seal bead and StoFentra Gutter Profi PDF DWG
Sto-HQ-EN_GEN-0430-01_2021-06-28 Reveallintel (horizontal section) Connection of the reveal to a set-back window made of timber and aluminium using a seal bead PDF DWG
Sto-HQ-EN_GEN-0430-03_2021-06-28 Reveallintel (horizontal section) Connection of the reveal to a set-back window made of timber and aluminium using a seal bead PDF DWG
Sto-HQ-EN_GEN-0430-07_2022-05-03 Reveallintel (horizontal section) Connection of the reveal to a set-back window made of timber and aluminium using a Sto-Seal Bead Alu-flex PDF DWG
Sto-HQ-EN_GEN-0430-08_2020-03-01 Reveallintel (horizontal section) Connection of the reveal to a set-back window using a seal bead e.g. Sto-Seal Bead Elastico PDF DWG
Sto-HQ-EN_GEN-0431-01_2020-05-19 Reveallintel (horizontal section) Connection of the reveal to a set-back window using joint sealing tape and render stop profile PDF DWG
Sto-HQ-EN_GEN-0440-01_2021-03-16 Reveallintel (horizontal section) Connection of the reveal to a set-forward window with Sto-Seal Bead Expert Pro PDF DWG
Sto-HQ-EN_GEN-0441-01_2021-03-16 Reveallintel (horizontal section) Connection of the StoElement Pronto L-100 L-300 and StoFentra Profi to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0441-02_2021-03-16 Reveallintel (horizontal section) Connection of the StoElement Pronto L-100 L-300 and StoFentra Profi to a set-back window PDF DWG
Sto-HQ-EN_GEN-0441-03_2021-03-16 Reveallintel (horizontal section) Connection of the StoElement Pronto L-100 L-300 and StoFentra Profi to a set-forward window PDF DWG
Sto-HQ-EN_GEN-0441-04_2021-05-16 Reveallintel (horizontal section) Connection of the reveal to a set-forward window with pre-wall mounting system and StoElement Pronto L-100 L-300 PDF DWG
Sto-HQ-EN_GEN-0450-01_2022-12-01 Reveallintel (horizontal section) Connection to a Flat duct with ventilation grid PDF DWG
Sto-HQ-EN_GEN-0442-02_2021-12-01 Reveal/lintel (horizontal section): Connection of the StoElement Pronto P-101 / P-300 and StoFentra Profi to a set-back window PDF DWG
Sto-HQ-EN_GEN-0442-03_2021-12-01 Reveal/lintel (horizontal section): Connection of the StoFentra Duo and the StoElement Pronto P-101 / P-300, StoElement Pronto K-100 / K-300 with a second waterproofing layer in accordance with the RAL directive PDF DWG

No. Description PDF DWG
Sto-HQ-DE_GEN-0515-05_2022-09-14 Window sill (vertical section): Connection of the Sto-Window Sill Stone without end profile and StoFentra EPS Wedge 5° with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0500-02_2022-04-05 Window sill (vertical section): Connection of StoFentra Profi with StoFentra Window Sill Bracket PDF DWG
Sto-HQ-EN_GEN-0500-01_2020-01-01 Window sill (vertical section): Connection of StoFentra Profi, area at risk of impact with StoPanel Plus (8 mm) PDF DWG
Sto-HQ-EN_GEN-0500-03_2022-07-06 Window sill (vertical section): Connection of the reveal to a set-forward window with pre-wall mounting system and StoFentra Profi PDF DWG
Sto-HQ-EN_GEN-0501-01_2021-07-02 Window sill (horizontal section): Connection of StoFentra Profi Custom Variant to a set-back window with a tilted window reveal PDF DWG
Sto-HQ-EN_GEN-0501-02_2020-01-01 Window sill (horizontal section, vertical section, view): Connection of StoFentra Profi PDF DWG
Sto-HQ-EN_GEN-0501-03_2021-07-02 Window sill (horizontal section): Connection of StoFentra Profi Custom Variant to a window flush with the masonry and a tilted window reveal PDF DWG
Sto-HQ-EN_GEN-0501-04_2021-06-25 Window sill (vertical section): Connection of StoFentra Gutter Profi PDF DWG
Sto-HQ-EN_GEN-0510-01_2020-01-01 Window sill (vertical section): Connection of the StoFentra Duo with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0510-02_2020-01-01 Window sill (vertical section): Connection of the StoFentra Duo using the StoFentra Guard waterproofing system in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0511-01_2020-01-01 Window sill (vertical section): Connection of the StoFentra Duo using the StoFentra Guard waterproofing system PDF DWG
Sto-HQ-EN_GEN-0512-01_2020-03-18 Window sill (vertical section): Connection of the StoFentra Duo and the StoElement Pronto K-100 / K-300 with a second waterproofing layer in accordance with the RAL directive PDF DWG
Sto-HQ-EN_GEN-0515-01_2019-07-04 Window sill (vertical section): Connection of the Sto-Window Sill Stone and the StoElement Pronto K-100 / K-300 PDF DWG
Sto-HQ-EN_GEN-0515-02_2020-01-01 Window sill (vertical section): Connection of a natural stone window sill using a second waterproofing layer in accordance with the RAL directive and Sto-Parapet Profile PDF DWG
Sto-HQ-EN_GEN-0515-03_2020-01-01 Window sill (vertical section): Connection of the StoFentra Duo with a second waterproofing layer in accordance with the RAL directive and Sto-parapete profile. PDF DWG
Sto-HQ-EN_GEN-0541-01_2020-01-01 Window sill (vertical section): Connection of StoFentra Profi and the StoElement Pronto L-100 / L-300 to a window flush with the masonry PDF DWG
Sto-HQ-EN_GEN-0513-03_2020-04-01 Window sill (vertical section): Connection of the StoFentra Duo with a second waterproofing layer made of reinforced base coat and StoSeal L 110 PDF DWG
Sto-HQ-EN_GEN-0515-04_2022-09-14 Window sill (vertical section): Connection of the Sto-Window Sill Stone with end profile and the StoElement Pronto K-100 / K-300 PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0610-01_2020-01-01 Roller shutter/ window blinds (horizontal section): Connection of the reveal to a window with a shutter guide track, StoFentra Profi with notch using a seal bead PDF DWG
Sto-HQ-EN_GEN-0610-02_2019-07-11 Roller shutter/ window blinds (horizontal section): Connection of the reveal to a window with a shutter guide track, StoFentra Profi Niche using a seal bead PDF DWG
Sto-HQ-EN_GEN-0605-01_2020-01-01 Roller shutter/ window blinds (horizontal section): Connection to a shutter guide track PDF DWG
Sto-HQ-EN_GEN-0607-01_2023-01-01 Roller shutter/ window blinds (horizontal section): Connection of the reveal to a window with StoFentra Duo and a shutter guide track PDF DWG
Sto-HQ-EN_GEN-0610-03_2020-05-05 Roller shutter/ window blinds (horizontal section): Connection of the reveal to a window flush with the masonry with a shutter guide track, StoFentra Profi with notch using a seal bead PDF DWG
Sto-HQ-EN_GEN-0615-01_2019-08-01 Roller shutter/ window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box, without additional insulation on the roller shutter box PDF DWG
Sto-HQ-EN_GEN-0615-04_2020-11-04 Roller shutter/ window blinds (vertical section): Connection to a visible roller shutter box, using Sto-Plinth Profile PH / PH-A and joint sealing tape PDF DWG
Sto-HQ-EN_GEN-0616-01_2019-08-01 Roller shutter/ window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box, with < 4 cm additional insulation on the roller shutter box PDF DWG
Sto-HQ-EN_GEN-0620-01_2020-11-04 Roller shutter/ window blinds (vertical section): Connection to a load-bearing and dimensionally stable roller shutter box, with ≥ 4 cm additional insulation on the roller shutter box PDF DWG
Sto-HQ-EN_GEN-0627-01_2020-01-01 Roller shutter/ window blinds (vertical section): Connection of a roller shutter cover with StoPanel Plus (12 mm) to a sufficiently load-bearing sub-construction with additional insulation PDF DWG
Sto-HQ-EN_GEN-0629-01_2022-03-21 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0629-02_2022-03-21 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG
Sto-HQ-EN_GEN-0629-03_2023-07-19 Roller shutter/ window blinds (vertical section): Connection of a roller blind cover with StoPanel Plus (12 mm) and Sto-Edge Protection Profile GT PDF DWG
Sto-HQ-EN_GEN-0630-01_2021-05-21 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) directly on the wall construction and retrofitted insulation PDF DWG
Sto-HQ-EN_GEN-0631-01_2022-12-06 Roller shutter/window blinds (vertical section): Connection of a thermally separated roller shutter with cover sheet metal and slope PDF DWG
Sto-HQ-EN_GEN-0631-02_2022-12-06 Roller shutter/window blinds (vertical section): Connection of a thermally separated roller shutter PDF DWG
Sto-HQ-EN_GEN-0632-01_2020-01-01 Roller shutter/window blind (horizontal section, view): Connection of a non-load-bearing window blind box (length > 20 m) with StoPanel Plus (20 mm) and expansion joint PDF DWG
Sto-HQ-EN_GEN-0636-01_2021-07-29 Roller shutter/ window blinds (vertical section): Connection of a non-load-bearing window blind box with fixing and thermal separation already available on-site PDF DWG
Sto-HQ-EN_GEN-0670-01_2022-11-22 Roller shutter/window blinds (vertical section): Connection of a roller shutter cover underneath the balcony slab with StoPanel Plus (20 mm) to a sufficiently load-bearing sub-construction PDF DWG
Sto-HQ-EN_GEN-0627-02_2022-03-08 Roller shutter/ window blinds (vertical section): Connection of a roller shutter cover with StoPanel Plus (12 mm) to a sufficiently load-bearing sub-construction with ≥ 4 cm additional insulation PDF DWG
Sto-HQ-EN_GEN-0629-04_2022-03-18 Roller shutter/ window blinds (vertical section): Connection of a projecting roller blind cover with StoPanel Plus (20 mm) with an edge protection profile PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0705-01_2020-01-15 Balcony/terrace (vertical section): Connection to a terrace with sheeting already available on-site and Sto-Joint Flank Profile PDF DWG
Sto-HQ-EN_GEN-0710-01_2021-12-02 Balcony/terrace (vertical section): Connection to a balcony or a terrace as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0710-02_2021-12-02 Balcony/terrace (vertical section): Connection to a balcony or a terrace as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0710-03_2021-12-02 Balcony/terrace (vertical section): Connection to a balcony or a terrace as refurbishment proposal PDF DWG
Sto-HQ-EN_GEN-0726-01_2023-02-01 Balcony/terrace (vertical section): Connection to a terrace or a flat roof using liquid synthetic waterproofing (e.g. Kemperol) and protection against mechanical damage PDF DWG
Sto-HQ-EN_GEN-0726-02_2022-09-09 Balcony/terrace (vertical section): Connection to a terrace or a flat roof with Sto-Render Stop Profile and StoMurisol BD 2K PDF DWG
Sto-HQ-EN_GEN-0727-01_2020-05-18 undefined PDF DWG
Sto-HQ-EN_GEN-0727-03_2023-05-10 Balcony/Terrace (Vertical section): Connection to a terrace or a flat roof e.g. over an underground parking PDF DWG
Sto-HQ-EN_GEN-0730-01_2019-10-09 Balcony/terrace (vertical section): Connection of a balcony threshold with a second waterproofing layer in accordance with the RAL directive PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0800-01_2020-01-01 Structural expansion joint (horizontal section) Offset joint with Sto-Expansion Joint Profile E PDF DWG
Sto-HQ-EN_GEN-0800-02_2019-12-01 Structural expansion joint (horizontal section) Joint with Sto-Expansion Joint Profile E with Sto-Expansion Joint Cover E PDF DWG
Sto-HQ-EN_GEN-0805-01_2019-12-01 Structural expansion joint (horizontal section) Joint with Sto-Expansion Joint Profile V with Sto-Expansion Joint Cover V in an internal corner PDF DWG
Sto-HQ-EN_GEN-0830-01_2021-12-22 Structural expansion joint (vertikal section): Joint with Sto-Plinth Profile PH, Sto-Joint Flank Profile and Sto-Expansion Joint Tape PDF DWG

No. Description PDF DWG
Sto-HQ-EN_GEN-0900-01_2020-01-01 Other (vertikal section): Sto-Rusticated Facade Type I PDF DWG
Sto-HQ-EN_GEN-0900-02_2020-01-01 Other (vertikal section): Sto-Rusticated Facade Type II PDF DWG
Sto-HQ-EN_GEN-0900-03_2020-01-01 Other (vertikal section): Sto-Rusticated Facade Type III PDF DWG
Sto-HQ-EN_GEN-0950-01_2020-01-01 Dowel layout for Sto-EPS Insulation Board 1000 mm x 500 mm – 4 dowels/m² to 16 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-02_2020-01-01 Dowel layout for mineral wool – insulation boards 800 mm x 625 mm – 4 dowels/m² to 14 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-03_2020-03-01 Dowel layout for mineral wool – insulation boards 120 cm x 40 cm – 4 dowels/m² to 16 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-04_2020-01-01 Dowel layout for mineral wool Lamella – Insulation boards 1200 mm x 200 mm – 4 dowels/m² to 14 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-05_2020-01-01 Dowel layout for fixing with anchors through the mesh – 4 dowels/m² to 16 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-06_2020-01-01 Anchor layout for Sto-EPS Boards, 1000 mm x 500 mm: 4-16 anchors/m² in the board area PDF DWG
Sto-HQ-EN_GEN-0950-07_2020-01-01 Anchor layout for Sto-Stone Wool Insulation Boards, 800 mm x 625 mm: 4-10 anchors/m² in the board area PDF DWG
Sto-HQ-EN_GEN-0950-08_2020-01-01 Anchor layout for Sto-Stone Wool Insulation Boards, 1200 mm x 400 mm: 4-14 anchors/m² in the board area PDF DWG
Sto-HQ-EN_GEN-0950-09_2020-04-01 Dowel layout for mineral wool – insulation boards 800 mm x 625 mm – 4 dowels/m² to 10 dowels/m² in the board area PDF DWG
Sto-HQ-EN_GEN-0950-10_2020-04-01 Dowel layout for mineral wool – insulation boards 800 mm x 625 mm – 11 dowels/m² to 16 dowels/m² n the board area PDF DWG
Sto-HQ-EN_GEN-0950-11_2020-01-01 Dowel layout for Sto-Insulation Board PIR BLF 1000 mm x 500 mm – 4 dowels/m² to 16 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-12_2020-01-01 Dowel layout for Sto-Soft Fibre Board M 039 1200 mm x 400 mm – 4 dowels/m² to 12 dowels/m² PDF DWG
Sto-HQ-EN_GEN-0950-13_2020-03-01 Anchor layout for Sto-mineral wool – Insulation boards 120 cm x 40 cm – 4 anchors/m² to 16 anchors/m² in the board area PDF DWG
Sto-HQ-EN_GEN-0950-14_2021-06-01 Dowel layout for mineral wool Lamella – Insulation boards 1200 mm x 200 mm: Additional dowelling for insulation thicknesses above 200 mm in accordance with the technical approval No. Z-33.44-134, 3 dowels/insulation board or 2,5 dowels/m PDF DWG
Sto-HQ-EN_GEN-0950-15_2021-06-01 Dowel layout for mineral wool Lamella – Insulation boards 1200 mm x 200 mm: Additional dowelling for insulation thicknesses above 200 mm in accordance with the technical approval No. Z-33.44-134, 3 dowels/insulation board or 2,5 dowels/m PDF DWG

Ειδικές λεπτομέρειες για το σύστημα StoTherm Classic

No. Description PDF DWG
Sto-HQ-EN_STC-0116_2018-05-01 Plinth (vertical section): Ground and splash water zone with Sto-Perimeter Insulation Board, only for StoTherm Classic PDF DWG

No. Description PDF DWG
Sto-HQ-EN_STC-0242_2018-05-01 External wall / system transition (vertical section): Transition between different insulant thicknesses, only for StoTherm Classic PDF DWG

Copyright © 2024 Sto Hellas - All rights reserved | www.stohellas.gr | Επικοινωνία | www.sto.com

Φυλλάδια

Newsletter

Επικοινωνία

www.sto.com

Copyright © 2024 Sto Hellas - All rights reserved